Where innovation meets protection
01279 969 060
Grade 3 High Security Products
Our range of tried and tested Seismic detectors have been the UK's Banking and High Security Sectors go to devices for over 30 years.
Specifically designed for round the clock monitoring, providing protection against vandalism and theft.
Constantly evolving to ensure we maintain the highest standards of protection that this sector requires.
All of the products on this page now use our latest Grade 3+ Dual Smart Sensor PCB
All our CSE sensors have 13 pre-programmed multi mode sensitivity levels built-in
If required, further adjustments can made on-site by an engineer using the the custom sensor app*. (*requires Android device)
No other seismic sensor currently in the marketplace has this unique dual sensor detection technology
Virtually eliminating false alarms that could be caused by environmental disturbances, coupled with a very large area of detection.
Full specifications can be found from the data sheets in the Support area.**
Retrofits and upgrades to older legacy Capella and URA/ LFS products which no longer meet
the required standards are quick and easy to fit with no need to re-drill the safe/ATM.
Easy to install with all alarm systems, including PACOM and Honeywell Alarm Control Panels
Please note: For all 1st Gen Capella products the drilling /mounting holes are in the same position.
To upgrade from an older URA / LFS unit some products may require a mounting conversion plate.
If your unsure what to fit to a particular make or model, give us a call or download our compatibility list from the support area.
We manufacture in house,in the UK, therefore we can quickly modify or customize any of our products to your specific requirements.
** Note for security reasons data sheets and installation manuals
can only be downloaded from the Support area.
To access this area please contact us to register.
ERS Hasp Lock- Part No: CSE-271
Electronic Hasp Slide Bolt Lock
(Lock only no seismic sensor)
With Front, Rear and Internal Tamper protection and Bolt open/closed monitoring.
Unit can be mounted in place of an older Hasp Lock unit using existing mounting holes, however note that unit is 55mm longer than earlier generation unit.
Optional magnetic door contact and tilt alarm add-on kit also available to order.
Register to download data sheet from technical area.
ERS/EVD Keyslide- Part No: CSE-369
2nd Gen Key Slide Grade 3+ Protection
Replacement/Upgrade for JS168 and LFS 5
With Dual Seismic Smart Vibration Sensor, now with built in Tilt alarm as standard
Comes with mounting plate for easy upgrade from Ist Gen JS168 and LFS-5 units.
Optional door contact kit also available to order
ATM 7 v2 - Part No: CSE-301
2nd Gen Grade 3+ ATM Protection
With Dual Seismic Smart Sensor Inc Tilt alarm
Huge 8+ Meter Sq Detection area, Compared to 150mm of Older LFS unit
Can be be used as a direct upgrade to older URA ATM 7 and LFS7 units
Door Mounted Protection for Flush or Raised doors
44mm Hasp door spacers available for raised doors (NCR 6625) - See our spacers and mounting brackets page.
ATM 6 v2 - Part No: CSE-300
Side Mounted Protection for Flush Safe Doors
2nd Gen Grade 3 ATM Protection
With Dual Seismic Smart Sensor Inc Tilt
ATM 8 v2 - Part No: CSE-346
Side Mounted Wrap Around Protection for Flush Safe Doors
2nd Gen Grade 3+ ATM Protection
With Dual Seismic Smart Sensor Inc Tilt
ATM 13 - Part No: CSE-313
Door Mounted sensor with 12mm dia steel sprung solenoid bolt
for speed shut protection.
Direct Upgrade replacement for LFS12/13 (no drilling required)
Grade 3+ ATM Protection
With Dual Seismic Smart Sensor Inc Tilt
Huge 8+ Meter Sq Detection area, Compared to 150mm of Older LFS unit
This unit is also available as a direct upgrade to the LFS13 no drilling of safe is required, simply remove old unit and stress pads,
fit mounting conversion plates for unit and hasp then bolt the CSE313 to the mounting plate.
ATM 14 - Part No: CSE314 (LFS12 Replacement/ Upgrade)
Door Mounted sensor with 10mm manual solenoid brass bolt.
Essentially this is a smaller version of the ATM7v2.
Ideal for the smaller type under counter TCR machines.
Grade 3+ ATM Protection
With Dual Smart Sensor Inc Anti Tilt alarm
Comes complete with LFS Conversion mounting plates
Huge 8+ Meter Sq Detection area, Compared to 150mm of Older LFS unit
This unit is also available as a direct upgrade to the LFS12
NO re-drilling of the safe is required, simply remove old unit and stress pads, fit mounting conversion plates for unit and hasp then bolt the CSE314 to the mounting plate.
Sign up to our support area for in depth upgrade information.
ATM 15 - Part No: CSE-315
Door Mounted sensor with sprung solenoid bolt
for speed shut protection.
Smaller Version of our ATM13
Grade 3 ATM Protection
With Dual Smart Sensor Inc Tilt
Huge 8+ Meter Sq Detection area, Compared to 150mm of Older LFS unit
Wall and Door Sensors
EVD v3 Part No: CSE-363
Standard Seismic Dual smart detector
Can be mounted on walls and doors
Huge 8+ Meter Sq Detection area
EVD-W Part No: CSE-364
Wall only sensor - Programmed specifically for 3mtr+ thick, wall, Ceiling and floor protection Core Drilling Prevention Security System
Huge 8+ Meter Sq Detection area
EVD-D Part No: CSE-365
Seismic Dual Smart sensor with built in magnetic door contact.
Ideal for smaller safes or securing other areas such as loft hatches etc
EVD Smart Detector Part No: CSE-366
(Direct LFS1/2 Upgrade replacement)
Seismic Dual Smart sensor including 360 degree tilt detection alarm
Huge 8+ Meter Sq Detection area.
This unit is a direct upgrade / replacement for LFS1/2 units.
No more pads and no re-drilling required.
Smoke Light Noise Detector
SLN Part No: CSE-161 (Discontinued Product - Limited Availability)
This ceiling mounted detector is ideally suited for all types of high-risk environment such as bank vaults, book rooms and safe deposit facilities. Although this device may be used in a standalone situation, the full benefit of the detector is realized when it is coupled with the advanced signal processing Explosion Vibration Detector (EVD).
Remote Head Zone Extender
RHD Part No: CSE-195
Seismic Zone Extender
Used in conjunction with legacy Capella Sensors to extend the area of coverage.
Note* The CSE-195 can be used with the newer CSE Grade 3 sensors but the unit must be in Acoustic only mode
Termination Boxes
We manufacture various steel tampered termination boxes please call or email for more information.
Double Pole Relay Modules
Can be used with all our units to aid in switching power to solenoid from alarm panel.
Two version available with either Screw less or Screwed terminal connectors
Grade 3 Sounder Unit
123db Sounder in steel Enclosure
with cover and rear tamper switches
Part Ref :CSE-267
Sounder Voltage 12 Volts DC
Sounder Operating Voltage range 6-16 Volts DC
Rated Current (Max) 260 mA
Minimum SPL @ 10cm 123 dBA
Tone or Pulse rate 3.0 pulse /Sec
Operating Temp. -20 — +60
Enclosure Construction 1.5mm Mild Steel
Rear and Cover Open Tamper Switches with Wago Screw-less connectors
Voltage free contacts rated at 0.1Amps @12 volts DC
Dimensions: 95mm(H) x 120mm(W) x 70mm(D)
Weight: 0.75
Cable Entries 2 x Bottom 1 x Rear cable entry holes
Colour: Stock colours are White , Grey and Textured Black Powder Coated Finishes or as specified by client